A residual lesion on the edge of a radiotherapy scar, after chemoradiotherapy for T3 rectal cancer. It does not lift on the scarred side. So the plane is chosen zone by zone, in one procedure: submucosal where it lifts, intermuscular through the scar, and full thickness only where the layers are fused, under REACT multipoint traction.
The core message in one minute: REACT used 'to stop being reactive', not being wedded to one technique, and why the plane is kept as superficial as possible while staying radical.
A rectal cancer, staged T3, has been treated with chemoradiotherapy. The tumour has downstaged well, but on the edge of a dense radiotherapy scar there is residual lesion. It is flatter than before. Biopsy shows dysplasia. It does not look invasive now, but this was a deeply invasive cancer.
The question here is not whether to resect. It is which plane to resect in.
"So we're using a REACT to stop being reactive."
The lesion sits right on the pivot between mucosa that lifts and mucosa that does not. On the lifting side, ESD works as usual. On the scarred side the submucosa is gone. Stay submucosal there and you are guessing, and "sometimes it comes out the specimen, sometimes it doesn't".
So the plane is chosen zone by zone, in one procedure:
The rule is to be as superficial as possible while staying radical. This patient had significant low anterior resection syndrome (LARS) symptoms after chemoradiotherapy and was very worried about more. Being superficial where the lesion allows it protects function. Going deep where the scar demands it protects the margin.
"The more superficial you are, while retaining radicality, because that's the critical part, the less symptoms a patient gets afterwards."
The lesion is marked widely before anything else. On the scarred side there is no lift at all, and after injection the lesion disappears from view. The marks are the only way to know where it is. Marking wide also leaves a runway: enough normal tissue outside the marks to start the incision without risking the lateral margin, close to the anal verge.
"Optical diagnosis equals potentially deep. Previous significant radiotherapy burden. That's when this sort of thing can happen."
Our PRIME algorithm (Pocket-detection method with Real-time Intraprocedural Muscle-retracting sign Evaluation) uses a pocket to look for the muscle-retracting sign, and changes plane from ESD to EID or full thickness when it is found. It is designed for lesions that lift, mainly treatment-naive ones. In the PRIME series of 47 early rectal cancers, R0 resection was 89.1% and R0 vertical margin 95.7% (Sorge, Argenziano et al., Endoscopy 2026).
Here there is no lift and no plane to make a pocket in. The same logic applies, plane selection driven by what lies under the lesion, but the decision is made in advance from the history and the lack of lift: "Optical diagnosis equals potentially deep. Previous significant radiotherapy burden." So the incision goes all the way around, and each zone gets the plane it needs.
"Maybe it takes us five minutes to put this on, but at that point you're so much more in control."
Once the incision is through, the layers can be read directly. Longitudinal muscle, circular muscle, and between them fused scar. On the scarred side the EID plane is suboptimal but workable. On the other side it opens cleanly. Defining the planes at both the back and the front of the lesion matters. If you don't, it is unclear where the dissection will come out, and you keep going under.
"If you don't define them at the back and the front, you're in a problem."
Traction is placed early, before the difficult part. REACT (Repositionable Elastic Adaptive Customisable Traction) uses elastic bands and clips linked at several points. It can be moved and re-tensioned as the dissection goes on. Colour-coding keeps the lesion-side anchors distinct from the counter-traction points.
It takes about five minutes to build. "At that point you're so much more control." In EID it has a second use: a band on the muscle pulls it away from the specimen, so the knife tip stays visible and the longitudinal muscle is protected.
REACT was described in a 59-case feasibility series from Ghent (Poortmans et al., Gastrointest Endosc 2026). As the team put it during this case: "We're using a REACT to stop being reactive."
Partway through, the EID line on the better side is turned up into the submucosa, simply by changing the angle of the knife. That side becomes ESD. The scarred side stays intermuscular, with partial full thickness where the layers were fused. The specimen comes out in one piece.
This is not purism or showing off. It is adapting the plane to the tissue, and not being wedded to one technique.
A defect with depth over the full-thickness zone, after radiotherapy, is not a routine ESD defect. Visible vessels are treated with the snare tip. Closure is attempted, but over fibrotic, irradiated tissue clips hold poorly, and the team accepts that it may not be fully possible. A single dose of antibiotics is given because the dissection was intermuscular and partially full thickness. This case is also a reminder that the consent conversation for a post-radiotherapy rectal resection differs from that for a standard rectal ESD.
More on the method: the PRIME algorithm case and the REACT traction system at react.gieqs.com.
Access the full course with expert demonstrations, case studies, and clinical pearls.